PIP-GK Series


 

  • This PIP-GK series is a brand new model with combined features from PIP-GE (PF1.0, high PV input voltage, battery-optional operation) and PIP-MS series (remote LCD display, built-in MPPT solar charger), with these NEW features — 

    SOLAR + UTILITY COMBINE OUTPUT

    • Available on GK models: output to load can now be combined from SOLAR+ UTILITY source simultaneously if solar power is insufficient.  This feature applies to both when battery is connected or also when unit is running in batteryless mode.  To avoid any misunderstanding, please note MAX output power from the inverter from any source(s) of power, singly or jointly, remains unchanged and is still the same as the designed rating (e.g. 3KW for 3024GK and 5KW for 5048GK).

    There are two models in this series:

    • 3024GK (3KW/24VDC, 80A MPPT, max 500Voc PV, max 4KW PV array)
    • 5048GK (5KW/48VDC, 80A MPPT, max 500Voc PV, max 5KW PV array)


    Starting 2019, 5048GK is now officially compatible with Pylontech battery’s BMS system through the dedicated BMS port.  A special data cable will be required and sold separately to facilitate the communication.  Note this BMS communication works only with Pylontech batteries.  For more information, please see Pylontech BMS information page.  (note: this feature does not exist on 3024GK)

    For more information, please download catalogs from tab page above or contact our sales office at sales@mppsolar.com.

    • NEW! Battery Optional
    • NEW! Improved Monitoring Features – Removable USB, RS232/RS485, Bluetooth, Android
    • NEW! Removable LCD Display Control Module
    • NEW! Reserved BMS Port for Pylontech BMS system (5048GK only)
    • 3KW/24V, 5KW/48V model
    • Max 80A MPPT solar charger and support up to 5kw PV array
    • High PV input volt up to 500V open circuit
    • Increased charging voltage up to 31.5V @ 24V, or 61V @ 48V
    • High frequency pure sine wave design
    • Suitable for Off-Grid or with Grid
    • Generator starter dry contact
    • Programmable parameters on LCD
    • Max up to 60A utility charging
    • Adjustable charging voltage
    • Lightweight, easy to install
    • 2X surge capacity
    • FREE monitoring software
    • LCD Display + LED indicators

    Using Generator as AC-Input

    • Generator power is recommended to be 50% larger than the inverter rating to reduce chances of overload.
    • Inverter-generator is recommended due to its cleaner output than conventional generators.  Unsuitable generator output may be rejected by the inverter.

  • **For WatchPower software please contact our Sales team sales@mppsolar.com directly.

 